1.
Neurosurg Rev ; 47(1): 215, 2024 May 11.
Article in English | MEDLINE | ID: mdl-38730072

ABSTRACT

BACKGROUND AND OBJECTIVES: Cerebral aneurysms in complex anatomical locations and intraoperative rupture can be challenging. Many methods to reduce blood flow can facilitate its exclusion from the circulation. This study evaluated the safety and efficacy of using adenosine, rapid ventricular pacing, and hypothermia in cerebral aneurysm clipping. METHODS: Databases (PubMed, Embase, and Web of Science) were systematically searched for studies documenting the use of adenosine, rapid ventricular pacing, and hypothermia in cerebral aneurysm clipping and were included in this single-arm meta-analysis. The primary outcome was 30-day mortality. Secondary outcomes included neurological outcomes by mRs and GOS, and cardiac outcomes. We evaluated the risk of bias using ROBIN-I, a tool developed by the Cochrane Collaboration. OpenMetaAnalyst version 2.0 was used for statistical analysis and I2 measured data heterogeneity. Heterogeneity was defined as an I2 > 50%. RESULTS: Our systematic search yielded 10,100 results. After the removal of duplicates and exclusion by title and abstract, 64 studies were considered for full review, of which 29 were included. The overall risk of bias was moderate. The pooled proportions of the adenosine analysis for the different outcomes were: For the primary outcome: 11,9%; for perioperative arrhythmia: 0,19%; for postoperative arrhythmia: 0,56%; for myocardial infarction incidence: 0,01%; for follow-up good recovery (mRs 0-2): 88%; and for neurological deficit:14.1%. In the rapid ventricular pacing analysis, incidences were as follows: peri operative arrhythmia: 0,64%; postoperative arrhythmia: 0,3%; myocardial infarction: 0%. In the hypothermia analysis, the pooled proportion of 30-day mortality was 11,6%. The incidence of post-op neurological deficits was 35,4% and good recovery under neurological analysis by GOS was present in 69.2%. CONCLUSION: The use of the three methods is safe and the related complications were very low. Further studies are necessary, especially with comparative analysis, for extended knowledge.


Subject(s)
Adenosine , Intracranial Aneurysm , Humans , Intracranial Aneurysm/surgery , Adenosine/therapeutic use , Hypothermia, Induced/methods , Treatment Outcome , Neurosurgical Procedures/methods , Cardiac Pacing, Artificial/methods
2.
J Am Heart Assoc ; 13(9): e034004, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38639381

ABSTRACT

BACKGROUND: An epicardial connection (EC) through the intercaval bundle (EC-ICB) between the right pulmonary vein (RPV) and right atrium (RA) is one of the reasons for the need for carina ablation for PV isolation and may reduce the acute and chronic success of PV isolation. We evaluated the intra-atrial activation sequence during RPV pacing after failure of ipsilateral RPV isolation and sought to identify specific conduction patterns in the presence of EC-ICB. METHODS AND RESULTS: This study included 223 consecutive patients who underwent initial catheter ablation of atrial fibrillation. If the RPV was not isolated using circumferential ablation or reconnected during the waiting period, an exit map was created during mid-RPV carina pacing. If the earliest site on the exit map was the RA, the patient was classified into the EC-ICB group. The exit map, intra-atrial activation sequence, and RPV-high RA time were evaluated. First-pass isolation of the RPV was not achieved in 36 patients (16.1%), and 22 patients (9.9%) showed reconnection. Twelve and 28 patients were classified into the EC-ICB and non-EC-ICB groups, respectively, after excluding those with multiple ablation lesion sets or incomplete mapping. The intra-atrial activation sequence showed different patterns between the 2 groups. The RPV-high RA time was significantly shorter in the EC-ICB than in the non-EC-ICB group (69.2±15.2 versus 148.6±51.2 ms; P<0.001), and RPV-high RA time<89.0 ms was highly predictive of the existence of an EC-ICB (sensitivity, 91.7%; specificity, 89.3%). CONCLUSIONS: An EC-ICB can be effectively detected by intra-atrial sequencing during RPV pacing, and an RPV-high RA time of <89.0 ms was highly predictive.


Subject(s)
Atrial Fibrillation , Cardiac Pacing, Artificial , Catheter Ablation , Heart Atria , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Female , Male , Catheter Ablation/methods , Middle Aged , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Cardiac Pacing, Artificial/methods , Aged , Heart Atria/physiopathology , Heart Atria/surgery , Treatment Outcome , Retrospective Studies , Pericardium/surgery , Pericardium/physiopathology , Heart Conduction System/physiopathology , Action Potentials , Electrophysiologic Techniques, Cardiac , Heart Rate/physiology
3.
Ann Noninvasive Electrocardiol ; 29(3): e13113, 2024 May.
Article in English | MEDLINE | ID: mdl-38563226

ABSTRACT

The anatomy of the His-Purkinje system has been studied, yet there remains a knowledge gap regarding the impact of His bundle pacing and its electrocardiographic implications. This case report highlights the presence of His-Purkinje system pathology without apparent clues on the surface electrocardiogram (EKG). By observing identical QRS morphology with varying HV intervals resulting from different pacing outputs, we demonstrate the presence of an electrical propagation block within the His bundle.


Subject(s)
Bundle of His , Purkinje Fibers , Humans , Electrocardiography/methods , Cardiac Pacing, Artificial/methods
5.
Tex Heart Inst J ; 51(1)2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38680081

ABSTRACT

Transcatheter aortic valve replacement is quickly becoming the standard of care for patients with severe aortic stenosis thanks to its minimally invasive nature and favorable outcomes. Recently, left ventricular pacing has been proposed as a safer alternative to traditional right heart pacing, which could simplify the transcatheter aortic valve replacement procedure overall, although procedural complications may still occur. This report describes a rare case of left ventricular pacing wire-induced acute severe mitral valve regurgitation during transcatheter aortic valve replacement.


Subject(s)
Aortic Valve Stenosis , Mitral Valve Insufficiency , Transcatheter Aortic Valve Replacement , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/physiopathology , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnosis , Acute Disease , Aged, 80 and over , Cardiac Pacing, Artificial/methods , Male , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Treatment Outcome , Ventricular Function, Left/physiology , Pacemaker, Artificial/adverse effects , Female , Mitral Valve/surgery , Mitral Valve/diagnostic imaging
7.
Tex Heart Inst J ; 51(1)2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38564374

ABSTRACT

This report discusses a case of transient 2:1 atrioventricular block with conduction system pacing 4 hours after leadless right ventricular pacemaker implantation in a 19-year-old patient with a history of cardioinhibitory syncope and asystole cardiac arrest but without preexisting atrioventricular block. The atrioventricular block was resolved spontaneously. Pacing morphology was suggestive of right bundle branch pacing. Neither 2:1 atrioventricular block nor conduction system pacing has previously been a reported outcome of right ventricular leadless pacemaker implantation. The report demonstrates that conduction system pacing with leadless devices is achievable. Further study of techniques, limitations, and complications related to intentional right ventricular leadless conduction system pacing is warranted.


Subject(s)
Atrioventricular Block , Pacemaker, Artificial , Humans , Young Adult , Adult , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Atrioventricular Block/etiology , Cardiac Pacing, Artificial/methods , Pacemaker, Artificial/adverse effects , Heart Conduction System , Heart Ventricles , Treatment Outcome
8.
J Emerg Med ; 66(4): e492-e502, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38453595

ABSTRACT

BACKGROUND: Transvenous pacemaker placement is an integral component of therapy for severe dysrhythmias and a core skill in emergency medicine. OBJECTIVE: This narrative review provides a focused evaluation of transvenous pacemaker placement in the emergency department setting. DISCUSSION: Temporary cardiac pacing can be a life-saving procedure. Indications for pacemaker placement include hemodynamic instability with symptomatic bradycardia secondary to atrioventricular block and sinus node dysfunction; overdrive pacing in unstable tachydysrhythmias, such as torsades de pointes; and failure of transcutaneous pacing. Optimal placement sites include the right internal jugular vein and left subclavian vein. Insertion first includes placement of a central venous catheter. The pacing wire with balloon is then advanced until electromechanical capture is obtained with the pacer in the right ventricle. Ultrasound can be used to guide and confirm lead placement using the subxiphoid or modified subxiphoid approach. The QRS segment will demonstrate ST segment elevation once the pacing wire tip contacts the endocardial wall. If mechanical capture is not achieved with initial placement of the transvenous pacer, the clinician must consider several potential issues and use an approach to evaluating the equipment and correcting any malfunction. Although life-saving in the appropriate patient, complications may occur from central venous access, right heart catheterization, and the pacing wire. CONCLUSIONS: An understanding of transvenous pacemaker placement is essential for emergency clinicians.


Subject(s)
Pacemaker, Artificial , Humans , Pacemaker, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Bradycardia/etiology , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/complications , Sick Sinus Syndrome/therapy
9.
Europace ; 26(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38457487

ABSTRACT

AIMS: Aveir VR performance and predictors for its pacing threshold (PCT) in a real-world cohort were investigated. METHODS: Electrical measurements at various stages of an Aveir VR implant were prospectively collected. Predictors for 3-month PCT were studied. A retrospective cohort of consecutive 139 Micra implants was used to compare the PCT evolution. High PCT was defined as ≥1.5 V, using a pulse width of 0.4 ms for Aveir and 0.24 ms for Micra. Excellent PCT was defined as ≤0.5 V at the respective pulse width. RESULTS: Among the 123 consecutive Aveir VR implant attempts, 122 (99.2%) were successful. The majority were of advanced age (mean 79.7) and small body size (mean BSA 1.60). Two patients (1.6%) experienced complications, including one pericardial effusion after device reposition and one intraoperative device dislodgement. Eighty-eight patients reached a 3-month follow-up. Aveir 3-month PCT was correlated with impedance at mapping (P = 0.015), tether mode (P < 0.001), end-of-procedure (P < 0.001), and mapping PCT (P = 0.035), but not with PCTs after fixation (P > 0.05). Tether mode impedance >470 ohms had 88% sensitivity and 71% specificity in predicting excellent 3-month PCT. Although it is more common for Aveir to have high PCT at end of procedure (11.5% for Aveir and 2.2% for Micra, P = 0.004), the rate at 3 months was similar (2.3% for Aveir and 3.1% for Micra, P = 1.000). CONCLUSION: Aveir VR demonstrated satisfactory performance in this high-risk cohort. Pacing thresholds tend to improve to a greater extent than Micra after implantation. The PCT after fixation, even after a waiting period, has limited predictive value for the chronic threshold. Low-mapping PCT and high intraoperative impedance predict chronic low PCT.


Subject(s)
Pacemaker, Artificial , Virtual Reality , Humans , Treatment Outcome , Retrospective Studies , Equipment Design , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods
10.
J Am Heart Assoc ; 13(4): e032386, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38348809

ABSTRACT

BACKGROUND: Metabolic disorder is noted for pacing-induced cardiomyopathy. The benefits of His bundle pacing over right ventricular (RV) pacing in preventing pacing-induced cardiomyopathy from a metabolic perspective are yet to be fully understood. METHOD AND RESULTS: Three pig groups were established for this study: sham control, RV pacing (RV pacing for 6 months), and His pacing (RV pacing for 6 months, followed by His bundle pacing for 3 months). Complete atrioventricular block was created in the last 2 groups. Left ventricular function and dyssynchrony were assessed via echocardiography, while proteins linked to metabolism, endoplasmic reticulum stress, and inflammation in left ventricular myocardium were examined. The RV pacing group had significantly more left ventricular mechanical dyssynchrony compared with the other groups. The RV pacing group exhibited triglyceride and diacylglycerol accumulation in cardiomyocytes and higher expression of binding immunoglobulin protein and tumor necrosis factor-α than the other groups. Additionally, the expression of CD36 was activated, while the expression of hormone-sensitive lipase was downregulated in the RV pacing group compared with the His pacing and sham control groups. Furthermore, the expressions of GLUT4 and pyruvate dehydrogenase were higher in the RV pacing group than the sham control and His pacing groups. Notably, the abnormal fatty acid and glucose metabolic pathways in the left ventricular myocardium during RV pacing could be corrected by His bundle pacing. CONCLUSIONS: His bundle pacing can mitigate the abnormal metabolism disorders, endoplasmic reticulum stress, and inflammation induced during RV pacing and may contribute to the superiority of conduction system pacing over RV pacing in reducing heart failure hospitalization.


Subject(s)
Bundle of His , Cardiomyopathies , Animals , Swine , Myocardium , Heart Ventricles , Glucose , Inflammation , Cardiac Pacing, Artificial/methods , Electrocardiography
11.
J Cardiovasc Electrophysiol ; 35(4): 802-810, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38409896

ABSTRACT

INTRODUCTION: The Mt. FUJI multicenter trial demonstrated that a delivery catheter system had a higher rate of successful right ventricular (RV) lead deployment on the RV septum (RVS) than a conventional stylet system. In this subanalysis of the Mt. FUJI trial, we assessed the differences in electrocardiogram (ECG) parameters during RV pacing between a delivery catheter system and a stylet system and their associations with the lead tip positions. METHODS: Among 70 patients enrolled in the Mt FUJI trial, ECG parameters, RV lead tip positions, and lead depth inside the septum assessed by computed tomography were compared between the catheter group (n = 36) and stylet group (n = 34). RESULTS: The paced QRS duration (QRS-d), corrected paced QT (QTc), and JT interval (JTc) were significantly shorter in the catheter group than in the stylet group (QRS-d: 130 ± 19 vs. 142 ± 15 ms, p = .004; QTc: 476 ± 25 vs. 514 ± 20 ms, p < .001; JTc: 347 ± 24 vs. 372 ± 17 ms, p < .001). This superiority of the catheter group was maintained in a subgroup analysis of patients with an RV lead tip position at the septum. The lead depth inside the septum was greater in the catheter group than in the stylet group, and there was a significant negative correlation between the paced QRS-d and the lead depth. CONCLUSION: Using a delivery catheter system carries more physiological depolarization and repolarization during RVS pacing and deeper screw penetration in the septum in comparison to conventional stylet system. The lead depth could have a more impact on the ECG parameters rather than the type of pacing lead.


Subject(s)
Cardiac Pacing, Artificial , Ventricular Septum , Humans , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Catheters , Electrocardiography/methods , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Ventricular Septum/diagnostic imaging
12.
Europace ; 26(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38340330

ABSTRACT

AIMS: A dual-chamber pacemaker with closed-loop stimulation (CLS) mode is effective in reducing syncopal recurrences in patients with asystolic vasovagal syncope (VVS). In this study, we explored the haemodynamic and temporal relationship of CLS during a tilt-induced vasovagal reflex. METHODS AND RESULTS: Twenty patients underwent a tilt test under video recording 3.9 years after CLS pacemaker implantation. Three patients were excluded from the analysis because of no VVS induced by the tilt test (n = 1) and protocol violation (n = 2). In 14 of the remaining 17 patients, CLS pacing emerged during the pre-syncopal phase of circulatory instability when the mean intrinsic heart rate (HR) was 88 ± 12 b.p.m. and systolic blood pressure (SBP) was 108 ± 19 mmHg. The CLS pacing rate thereafter rapidly increased to 105 ± 14 b.p.m. within a median of 0.1 min [inter-quartile range (IQR), 0.1-0.7 min] when the SBP was 99 ± 21 mmHg. At the time of maximum vasovagal effect (syncope or pre-syncope), SBP was 63 ± 17 mmHg and the CLS rate was 95 ± 13 b.p.m. The onset of CLS pacing was 1.7 min (IQR, 1.5-3.4) before syncope or lowest SBP. The total duration of CLS pacing was 5.0 min (IQR, 3.3-8.3). Closed-loop stimulation pacing was not observed in three patients who had a similar SBP decrease from 142 ± 22 mmHg at baseline to 69 ± 4 mmHg at the time of maximum vasovagal effect, but there was no significant increase in HR (59 ± 1 b.p.m.). CONCLUSION: The reproducibility of a vasovagal reflex was high. High-rate CLS pacing was observed early during the pre-syncopal phase in most patients and persisted, although attenuated, at the time of maximum vasovagal effect. REGISTRATION: ClinicalTrials.gov identifier: NCT06038708.


Subject(s)
Pacemaker, Artificial , Syncope, Vasovagal , Humans , Cardiac Pacing, Artificial/methods , Hemodynamics , Pacemaker, Artificial/adverse effects , Reproducibility of Results , Syncope, Vasovagal/diagnosis , Syncope, Vasovagal/prevention & control , Tilt-Table Test/methods
14.
Circ Arrhythm Electrophysiol ; 17(2): e012473, 2024 02.
Article in English | MEDLINE | ID: mdl-38284238

ABSTRACT

BACKGROUND: Right ventricular apical pacing (RVAP) can produce left ventricle dysfunction. Conduction system pacing (CSP) has been used successfully to reverse left ventricle dysfunction in patients with left bundle branch block. To date, data about CSP prevention of left ventricle dysfunction in patients with preserved left ventricular ejection fraction (LVEF) are scarce and limited mostly to nonrandomized studies. Our aim is to demonstrate that CSP can preserve normal ventricular function compared with RVAP in the setting of a high burden of ventricular pacing. METHODS: Consecutive patients with a high-degree atrioventricular block and preserved or mildly deteriorated LVEF (>40%) were included in this prospective, randomized, parallel, controlled study, comparing conventional RVAP versus CSP. RESULTS: Seventy-five patients were randomized, with no differences between basal characteristics in both groups. The stimulated QRS duration was significantly longer in the RVAP group compared with the CSP group (160.4±18.1 versus 124.2±20.2 ms; p<0.01). Seventy patients were included in the intention-to-treat analyses. LVEF showed a significant decrease in the RVAP group at 6 months compared with the CSP group (mean difference, -5.8% [95% CI, -9.6% to -2%]; P<0.01). Left ventricular end-diastolic diameter showed an increase in the RVAP group compared with the CSP group (mean difference, 3.2 [95% CI, 0.1-6.2] mm; P=0.04). Heart failure-related admissions were higher in the RVAP group (22.6% versus 5.1%; P=0.03). CONCLUSIONS: Conduction system stimulation prevents LVEF deterioration and heart failure-related admissions in patients with normal or mildly deteriorated LVEF requiring a high burden of ventricular pacing. These results are only short term and need to be confirmed by further larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT06026683.


Subject(s)
Cardiac Resynchronization Therapy , Cardiomyopathies , Heart Failure , Humans , Stroke Volume , Ventricular Function, Left/physiology , Heart Ventricles , Prospective Studies , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Cardiac Conduction System Disease , Treatment Outcome
15.
Pacing Clin Electrophysiol ; 47(2): 211-221, 2024 02.
Article in English | MEDLINE | ID: mdl-38265169

ABSTRACT

BACKGROUND: Conduction system pacing (CSP) is increasingly utilized to prevent and correct dyssynchrony. Barriers to CSP adoption include limited training, methodologic variability, laboratory slot allocation, and few data on learning curves. We report learning curves/clinical outcomes from a single experienced electrophysiologist who was new to CSP, and share gained insights. METHODS: Retrospective analysis of all patients who underwent attempted CSP implantation (2016-2023). Patient characteristics, ECGs, echocardiograms, fluoroscopy/procedure times, lead data were recorded at implant and follow-up. RESULTS: CSP leads were implanted successfully in 167/191(87.4%) patients with a follow-up of 278 ± 378 days. His-bundle pacing (HBP = 59) and left-bundle-area pacing (LBAP = 108) had similar procedure/fluoroscopy times, QRS duration decreases, and ejection fraction improvements (all p > NS). Eight HBP lead revisions were required for high capture thresholds LBAP demonstrated lower pacing thresholds, higher lead impedances, and greater R-wave amplitudes at implant and follow-up. After 25 HBP cases, implant pacing thresholds, fluoroscopy, procedural times did not decrease. After 25 LBAP cases, there were significant decreases in all these parameters (p < 0.05). A separate analysis in LBAP patients with recorded Purkinje signals showed no differences in paced ECG characteristics between patients with pre- QRS Purkinje signals versus patients with Purkinje signals post-QRS onset. CONCLUSIONS: Experienced implanters who are new to CSP can achieve steady-state procedural/fluoroscopy times after a learning curve of 25 implants. LBAP showed lower capture thresholds and higher success rates. Adequate depth of lead deployment (as determined by published parameters) does not require Purkinje potential to be pre-QRS. Operators new to CSP.can forego HBP and directly implement LBAP.


Subject(s)
Bundle of His , Learning Curve , Humans , Retrospective Studies , Cardiac Pacing, Artificial/methods , Cardiac Conduction System Disease , Electrocardiography/methods , Treatment Outcome
16.
Semin Cardiothorac Vasc Anesth ; 28(1): 38-46, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38284295

ABSTRACT

Since their initial approval by the Food and Drug Administration in 2016, leadless pacemakers have become increasingly prevalent. This growth has been driven by an improved adverse effect profile when compared to traditional pacemakers, including lower rates of infection, as well as eliminated risk of pocket hematoma and lead complications. More recently, technology enabling leadless synchronized atrioventricular pacing in patients with atrioventricular block has vastly expanded the indications for these devices. Anesthesiologists will increasingly be relied upon to safely care for patients with leadless pacemakers undergoing non-electrophysiology procedures and surgery. This article provides an overview of the technology, evidence base, current indications, and unique perioperative considerations for leadless pacemakers.


Subject(s)
Pacemaker, Artificial , Humans , Pacemaker, Artificial/adverse effects , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/etiology , Equipment Design
19.
Future Cardiol ; 20(1): 21-25, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38223918

ABSTRACT

Aim: Micra AV represents a leadless endocardial pacing system able to detect atrial contractions providing atrioventricular synchrony. A reduction of myocardial contractility may be detected in case of first-degree atrioventricular block (AVB). Materials & methods: In six patients with first-degree AVB (PQ interval ≥220 msec) was evaluated the left ventricle global longitudinal strain (LV GLS) by speckle tracking (ST) echocardiography during single-lead atrial sensing ventricular pacing (VDD) stimulation as compared with spontaneous rhythm (SR), 24-48 h after Micra AV implantation. Results: A statistically significant difference between the two modalities was observed (LV GLS during SR: -14.7% [interquartile range (IQR) 5.5], LV GLS during VDD pacing: -16.1% [IQR 5.2]; p value = 0.041). Conclusion: Our preliminary results suggest an improvement of myocardial contractility with VDD pacing as compared with SR.


What is this article about? The Micra AV is an electronic device placed in the heart chambers capable to supply the electrical activity of the heart. A reduction of cardiac contractility may be observed in patients with electrical disorders of the heart. What were the results? In six patients affected by electrical cardiac disorders, we observed an improvement of cardiac contractility using Micra AV as compared with the spontaneous electrical activity of the heart. What do the results of the study mean? The results of this study suggest that in patients carrying this electronic device should be preferred a specific modality of activation of the device as compared with the spontaneous electrical activity of the heart in order to improve the contractility of the cardiac walls.


Subject(s)
Atrioventricular Block , Heart Septal Defects , Pacemaker, Artificial , Humans , Heart Ventricles/diagnostic imaging , Cardiac Pacing, Artificial/methods , Atrioventricular Block/therapy , Heart Atria/diagnostic imaging
20.
Nat Commun ; 15(1): 64, 2024 Jan 02.
Article in English | MEDLINE | ID: mdl-38167848

ABSTRACT

There is an urgent clinical need for a treatment regimen that addresses the underlying pathophysiology of ventricular arrhythmias, the leading cause of sudden cardiac death. The current report describes the design of an injectable hydrogel electrode and successful deployment in a pig model with access far more refined than any current pacing modalities allow. In addition to successful cardiac capture and pacing, analysis of surface ECG tracings and three-dimensional electroanatomic mapping revealed a QRS morphology comparable to native sinus rhythm, strongly suggesting the hydrogel electrode captures the deep septal bundle branches and Purkinje fibers. In an ablation model, electroanatomic mapping data demonstrated that the activation wavefront from the hydrogel reaches the mid-myocardium and endocardium much earlier than current single-point pacing modalities. Such uniform activation of broad swaths of tissue enables an opportunity to minimize the delayed myocardial conduction of heterogeneous tissue that underpins re-entry. Collectively, these studies demonstrate the feasibility of a new pacing modality that most closely resembles native conduction with the potential to eliminate lethal re-entrant arrhythmias and provide painless defibrillation.


Subject(s)
Bundle of His , Hydrogels , Animals , Swine , Bundle of His/physiology , Cardiac Pacing, Artificial/methods , Purkinje Fibers , Electrodes , Arrhythmias, Cardiac/therapy , Electrocardiography/methods